Insulation Spray Machine
The 2400 series machine provides an economical, high production machine with low power requirements and reduced weight/size in your insulation truck or trailer system. The simple design and minimal moving parts provide a machine that is low maintenance and easy to repair. This compact, robust machine with its various options, will out-perform and out-last any machine in its class.
Weight and Dimensions
- 650 lbs (2-blower_
- 42” L x 22” W x 48” H
Airlock
- 20” long x 12” diameter 3” output for blowing hose, slide-out airlock
Power Requirements
- Double input, 20/30 amps. 120 vold or Single input, 30 amp 240 volt (two 3-stage blowers)
- Single input, 40 amp 240 volt (four 3-stage blowers or 5hp P.D. blower)
Blower Options
- 7.5 HP or 10 HP Positive displacement blower. (250 CFM, 350 CFM @ 5psi) 15,000 watt
Generator Size
- 22cu/ft. (4 bags)
- 7,500 watt (2-blower) 15,000 watt (4-blower or 5 h.p. P.D. blower)
Hopper Capacity
- Main Hopper: 11 cu./ft. (2 bags)
w/Hopper Extension: 22cu/ft. (4 bags)
Mechanical
- Large 11 cu./ft. hopper capacity fiber storage.
- Stainless slide-gate control provides precise control of fiber.
- High quality powder coating provides a long lasting corrosion resistant finish.
- Modular design with see-thru access panels for quick troubleshooting and maintenance.
- Slow speed positive feed ‘scalping’augers extend component life, while increasing safety.
- Large 12″ X 12″ quick release airlock is a durable, easily serviced component.
- High speed stainless shredder maximizes fiber conditioning, coverage, and production.
- High torque (1250 in./lb.) motor/reducer drive provides surplus power
- #50 chain and hardened sprockets, are rugged, corrosion resistant, and positive driving.
- Two integrally mounted 3-stage blowers w/check valve protection, outside air and reduced filter maintenance. (optional four blower or P.D. blower)
- 150 ft. remote cord w/cord hanger, offers convenient handling of remote device.
Electrical
- Safety Features: kill switch and manual controls promote increased operator safety and quick hazard response.
- Manual thermal overload protection of all motors and electrical components.
- Deluxe voltmeter for quick electrical diagnostics.

Posted in
Tags: 